    • 摘要: 矿井外部漏风率大小是衡量主要通风机运行状况和通风管理水平的重要指标之一,其测定方法的选择是现场技术人员进行漏风测定时面临的首要问题。依据矿井通风原理,分析了各种外部漏风测试方法的原理、步骤、适用条件等特性。以五沟煤矿外部漏风测定为实例,论述其方法选择的依据和过程。现场测试结果表明:在1#风机和2#风机运行状态下矿井外部漏风率分别为8.4%和7.85%,其中备用风机的装置漏风是主要的漏风源,必须采取有针对性的措施予以治理。测试结果为消除矿井漏风隐患、优化矿井通风系统提供科学的现场依据。

       

      Abstract: External air leakage ratio was one of important indexes to measure running status of main fan and ventilation management level in coal mine, and the selection of measurement methods was the chief issue for the field technique personnel when measuring external air leakage. According to coal mine ventilation principle, it analyzed the principle, process, and application condition for various measurement methods of external air leakage. Through taking external air leakage measurement of Wugou Coal Mine as the example, it discussed the basis and process of the methods selection. The field test results showed that external air leakage ratio was 8.4% and 7.85% respectively corresponding 1# fan and 2# fan running, the equipment air leakage of spare fan was the primary air leakage fountainhead, so specific measures must be applied to control air leakage. The test results provided scientific field reference for eliminating air leakage hidden trouble and optimizing coal mine ventilation system.

       

    /

    返回文章
    返回