    黄村分矿10111工作面隐伏陷落柱特大突水原因分析及防治措施

    Reasons Analysis and Prevention Measures of Water Bursting From Hidden Subsided Column in Huangcun Branch Coal Mine 10111 Working Face

    • 摘要: 通过奋进煤矿黄村分矿10111工作面隐伏陷落柱特大突水原因分析,实施了封堵突水点、地面三维地震勘探、地面钻探、井下物探、局部注浆加固等多项针对性强的水害防治对策,为矿井防治水工作提供了科学依据。

       

      Abstract: Through reasons analysis of water bursting from hidden subsided column at 10111 working face in Huangcun Branch of Fenjin Coal Mine, the study implemented a targeted water damage prevention measures, including plugging water bursting point, three-dimensional seismic exploration, ground drilling, underground geophysical exploration, partial grouting which provided a scientific basis for prevention and control of mine water disaster.

       

    /