郭恒. 显德汪煤矿采空区瞬变电磁探测实践[J]. 煤矿安全, 2019, 50(11): 140-143.
    引用本文: 郭恒. 显德汪煤矿采空区瞬变电磁探测实践[J]. 煤矿安全, 2019, 50(11): 140-143.
    GUO Heng. Practice of Transient Electromagnetic Detection in Goaf of Xiandewang Coal Mine[J]. Safety in Coal Mines, 2019, 50(11): 140-143.
    Citation: GUO Heng. Practice of Transient Electromagnetic Detection in Goaf of Xiandewang Coal Mine[J]. Safety in Coal Mines, 2019, 50(11): 140-143.

    显德汪煤矿采空区瞬变电磁探测实践

    Practice of Transient Electromagnetic Detection in Goaf of Xiandewang Coal Mine

    • 摘要: 针对河北邢台显德汪煤矿采空区及积水范围不明等问题,采用瞬变电磁法进行勘探。对于电磁干扰较为严重的区域采用限差、多项式拟合的方法进行校正。结果表明:矿井四采区2号煤层采空区局部存在积水区域,通过钻孔进行疏放,有效减小了采空区积水对工作面安全生产的影响。本次地面瞬变电磁法探测成果为矿井四采区正常安全开采提供了有力理论依据。

       

      Abstract: The transient electromagnetic method is used for exploration in the goaf of Xingtai Xiandewang Coal Mine in Hebei Province and the unknown water supply range. For areas with severe electromagnetic interference, the method of tolerance and polynomial fitting is used for correction. The results show that there is a water accumulation area in the goaf of No. 2 coal seam in the fourth mining area of the mine, which effectively reduces the impact of water accumulation in the goaf on the safe production of the working face by drilling drainage. The ground transient electromagnetic method has provided a powerful theoretical basis for the normal safe mining of the four mining areas.

       

    /