杨泽安, 王义亮. 综掘工作面湿式除尘条件下尘雾耦合数值模拟[J]. 煤矿安全, 2021, 52(11): 170-175.
    引用本文: 杨泽安, 王义亮. 综掘工作面湿式除尘条件下尘雾耦合数值模拟[J]. 煤矿安全, 2021, 52(11): 170-175.
    YANG Zean, WANG Yiliang. Numerical simulation of dust and spray coupling under wet dust removal condition in fully mechanized excavation face[J]. Safety in Coal Mines, 2021, 52(11): 170-175.
    Citation: YANG Zean, WANG Yiliang. Numerical simulation of dust and spray coupling under wet dust removal condition in fully mechanized excavation face[J]. Safety in Coal Mines, 2021, 52(11): 170-175.

    综掘工作面湿式除尘条件下尘雾耦合数值模拟

    Numerical simulation of dust and spray coupling under wet dust removal condition in fully mechanized excavation face

    • 摘要: 为了得到煤尘和喷雾液滴在风流作用下的运动规律,以某煤矿综掘工作面实际情况建立煤矿巷道及各主要设备几何模型,通过采用FLUENT软件的DPM模型对综掘工作面里的风流、煤尘和喷雾液滴进行耦合数值模拟。根据数值模拟结果得出:在长压短抽通风条件下配合附壁风筒使用的湿式除尘方法取得显著除尘效果,由附壁风筒出流的径向风流形成的风幕有效抑制了煤尘向巷道后方的运动;通过对瞬态结果的分析清晰知晓了煤尘和喷雾液滴的运移趋势;煤尘和喷雾液滴总体呈逐步向巷道后方扩散并逐渐被捕捉的趋势,且主要聚集在掘进机和截割面之间的区域,同时发现煤尘和喷雾液滴在30 s内逐渐减少,在掘进机司机处粒子浓度呈先急剧增加再逐步减少的规律。

       

      Abstract: In order to obtain the migration law of coal dust and spray droplets under the action of air current, the geometric model of coal mine roadway and major equipment is established based on the actual situation of a coal mine fully mechanized excavation face. The DPM model of the FLUENT software is used to carry out the coupling numerical simulation of air flow, coal dust and spray droplets in the fully mechanized excavation face. According to the numerical simulation results, the wet dust removal method combined with the wall-attached air duct under the condition of long pressure and short ventilation has achieved remarkable dust removal effect, and the air curtain formed by the radial air flow from the wall-attached duct has effectively inhibited the movement of coal dust toward the back of the tunnel. Through the analysis of transient results, we clearly know the migration trend of coal dust and spray droplets. Dust and spray droplets in general have been gradually spread to rear of roadway and gradually caught in the area between the machine and the cutting surface, also found that coal dust and spray droplets gradually reduce within 30 seconds, particle concentration in machine driver sharply increased first, and then gradually reduced.

       

    /