孙永新, 张浪, 杨旭, 刘彦青, 马强, 李伟, 张宏杰, 赵凯, 段思恭. 巷道风量全自动在线测试装置研制与应用[J]. 煤矿安全, 2022, 53(9): 251-256.
    引用本文: 孙永新, 张浪, 杨旭, 刘彦青, 马强, 李伟, 张宏杰, 赵凯, 段思恭. 巷道风量全自动在线测试装置研制与应用[J]. 煤矿安全, 2022, 53(9): 251-256.
    SUN Yongxin, ZHANG Lang, YANG Xu, LIU Yanqing, MA Qiang, LI Wei, ZHANG Hongjie, ZHAO Kai, DUAN Sigong. Development and application of automatic on-line measuring device for roadway air volume[J]. Safety in Coal Mines, 2022, 53(9): 251-256.
    Citation: SUN Yongxin, ZHANG Lang, YANG Xu, LIU Yanqing, MA Qiang, LI Wei, ZHANG Hongjie, ZHAO Kai, DUAN Sigong. Development and application of automatic on-line measuring device for roadway air volume[J]. Safety in Coal Mines, 2022, 53(9): 251-256.

    巷道风量全自动在线测试装置研制与应用

    Development and application of automatic on-line measuring device for roadway air volume

    • 摘要: 为了实现巷道风量在线准确测试,以王坡煤矿上寺头北翼回风巷和辅运大巷为研究对象,采用CFD方法模拟了矩形巷道和半圆拱巷道断面风速结构场;对比不同巷道风量条件下巷道断面平均风速分布区域,巷道风量大小对巷道断面内平均风速分布区域无影响;进一步获得巷道断面无因次风速结构场,为巷道断面平均风速分布区域内布置多个风速采集点准确求取巷道平均风速奠定了理论基础;以巷道断面无因次风速结构场为基础,根据巷道断面平均风速分布区域确定巷道平均风速数据采集点位置,构建了巷道断面平均风速九点采集法,准确获得巷道平均风速的同时能够检验风速传感器是否存在数据失真问题;结合巷道断面平均风速九点采集法,设计了分别适用于矩形巷道、拱形巷道的龙门式和折叠式巷道风量全自动在线测试装置,根据巷道平均风速数据采集点位置定制设计测试装置结构尺寸与风速传感器运动轨迹。在王坡煤矿10个测风站位置部署了巷道风量全自动在线测试装置,人工测风数据和装置测风数据之间相对误差小于8%,研究表明巷道风量全自动在线测试装置的测风精度能够满足矿井通风要求,同时能够实现矿井多个巷道风量同步在线测试。

       

      Abstract: In order to realize the on-line and accurate measurement of roadway air volume, taking the return air roadway and auxiliary transportation roadway in Shangsitou north wing of Wangpo Coal Mine as the research object, the wind speed structure field of rectangular roadway and semi-circular arch roadway section was simulated by CFD method, and the regional distribution of average wind speed in roadway section under different air volume conditions of the same roadway section was compared. The air volume basically had no effect on the regional range and location of the average wind speed distribution of the roadway section and the dimensionless wind velocity structure field of roadway section was further obtained, which was the theoretical foundation for arranging multiple wind speed collection points in the roadway section average wind speed distribution area to accurately calculate the roadway average wind speed. Based on the dimensionless wind speed structure field of roadway section, the position of data acquisition point of roadway average wind speed was determined according to the distribution area of roadway section average wind speed, and the nine point acquisition method of roadway section average wind speed was constructed, which could accurately obtain the roadway average wind speed and check whether there was data distortion in the wind speed sensor. Combined with the nine point acquisition method of roadway section average wind speed, the gantry and folding fully automatic on-line test device for roadway air volume suitable for rectangular roadway and arch roadway were designed respectively. The structural size of the test device and the motion track of wind speed sensor were customized according to the position of roadway average wind speed data acquisition point. The fully automatic on-line test device for roadway air volume was deployed at 10 wind measuring stations in Wangpo Coal Mine. The relative error between manual wind measurement and device wind measurement data was less than 8%. The research showed that the wind measurement accuracy of the fully automatic on-line test device for roadway air volume could meet the mine requirements, and could realize the synchronous on-line measurement of the air volume of multiple roadways in the mine.

       

    /

    返回文章
    返回