煤仓自燃液态CO2降温规律实验研究

    Experimental study on cooling law of spontaneous combustion by liquid CO2 injection in coal bunker

    • 摘要: 煤仓作为大型储煤场所,因漏风和烟囱效应易发生自燃。为研究液态CO2对煤仓自燃的处置效果,模拟煤仓结构搭建了煤仓液态CO2降温实验台,测试了煤仓在液态CO2注入过程中与停注后温度变化规律,并分析了高温区域温度场变化情况。结果表明:液态CO2注入煤仓过程中,主要降温区域集中在液态CO2释放口以及渗流通过区域,a、b、d平面平均温度分别下降22.7、33.0、10.2 ℃,降温区域分别为相变降温区、渗流降温区和对流降温区;停注后,相比于注入前,上、下部高温区域温度分别下降22.3、16.8 ℃,煤仓内煤体温度变化主要依靠煤体温差传导换热及低温干冰升华吸热。

       

      Abstract: As a large coal storage yard, coal bunker is prone to spontaneous combustion due to air leakage and chimney effect. In order to study the disposal effect of liquid CO2 on spontaneous combustion of coal bunker, a liquid CO2 cooling test bench was built to simulate the structure of coal bunker. The temperature variation laws of the coal bunker during the injection of liquid CO2 and after the injection was stopped were tested, and the variation of the temperature field in the high-temperature area was analyzed. The results show that during the injection of liquid CO2 into the coal bunker, the main cooling areas are concentrated at the liquid CO2 release port and the seepage passage area; the average temperatures of the a, b, and d planes decreased by 22.7 ℃, 33.0 ℃, and 10.2 ℃ respectively. The cooling areas are the phase change cooling area, seepage cooling area, and convection cooling area respectively. After the injection was stopped, compared with the temperature before the injection, the temperatures in the upper and lower high-temperature areas decreased by 22.3 ℃ and 16.8 ℃ respectively. The temperature change of the coal body in the coal bunker mainly relied on the heat transfer through the temperature difference conduction of the coal body and the heat absorption by the sublimation of low-temperature dry ice. At the same time, it indicates that during the fire extinguishing process in the coal bunker.

       

    /

    返回文章
    返回